The Component Humidifier
Component Template
The Humidifier.e-ctpl component template is located in the Component template library folder HVAC Systems.
Integration Into a Scheme
Please note the Special Features of the HVAC Components. The following figure shows an example of how to integrate the component into a scheme.
The Humidifier follows a Heating Battery.
How the Component Works
The prerequisite for adjusting the water content in the Humidifier component is the previous adjustment of the required air Temperature specified in the Input data of the Air Demand component. The temperature must be reached in the preceding components, e.g., a Heating Battery.
Input Data
First set the Nominal humidification quantity as Design parameter in l/h, m3/h, or l/s.
Then select the Type of humidifier:
For both Types of humidifier, you can set the Relative humidity (in combination with the Air temperature) or the Mixing ratio.