The Component Steam Generator
Component Template
The component template Steam_Generator.e-ctpl is located in the Component template library folder Steam Supply.
Integration Into a Scheme
The following figure shows the reference case of tutorial 34 as an example.
You can also see how the steam generator works in tutorial 33.
How the Component Works
Please note the important information on the material model and the insertion of the pins in the article Fuel Special Features. The optional pins for connecting the Fresh Air component appear if the fuel model Considering composition is activated.
The steam generator’s Own power and steam demand can be specified. The optional electricity pin on the component appears on the scheme if there is an Electric own consumption.